فرستنده سطح رادار OPTIWAVE 3500 برند کرونه

۰ ریال

هم اکنون در انبار موجود نیست - اما میتوانید این محصول را پیش خرید کنید

توضیحات

Radar (FMCW) level transmitter for liquids with hygienic requirements

  • Continuous, non-contact level measurement in small and narrow vessels, small storage tanks and agitated tanks
  • 80 GHz radar, flush-mounted Lens antenna
  • Measuring range: 0…50 m / 164 ft
  • -40…+150°C / +302°F; -1…25 barg / -14.5…362 psig

Specifications

Depending on selected device configuration

General information

Product type Level transmitter
Product family name OPTIWAVE
Product positioning For liquids with hygienic requirements
Measurement variables Distance, Level, Mass, Reflection, Volume
Measurement principle Radar
Level measurement type Continuous measurement
Contact to measured medium No
Interface measurement No
Redundancy No
Measured media Liquids, Slurries, Pastes
Measuring range (liquids) 0…50 m/
0…164 ft
Ambient temperature -40…+80°C/
-40…+176°F
Measuring point Pressurised tank, Open tank, Open basin

Operating conditions

Process pressure -1…25 barg/
-14.5…362 psig
Process temperature -40…+150°C/
-40…+302°F

Materials

Antenna Polyetheretherketone (PEEK)

Process connections

Hygienic connections Collar ferrule with nut (DIN 11851): DN40, DN50
Varivent®: N
Collar ferrule with nut (SMS 1147): 51 mm
Tri-Clamp®: 1½”, 2″
Clamp (ISO 2852): 25, 33.7, 38, 40, 51
NEUMO BioControl®: DN50
Collar ferrule (DIN 11864-1A): DN40, DN50

Approvals/Standards

Ingress protection IP66/68, NEMA4X/6P
Certificates/Approvals Ex ATEX, cQPSus, IECEx, NEPSI, EAC Ex
Certificates/Approvals Hygienic FDA, EHEDG, EC 1935/2004, EC2023/2006, EU 10/2011
Certificates/Approvals Others WHG, CRN / ASME B31.3
Certificates/Approvals Safety SIL 2/3
NAMUR compliance NE 107, NE 21, NE 43, NE 53

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA

Accuracy

Accuracy (liquids) ±2 mm/
±0.08 in
با توجه به نوسانات نرخ ارز، لطفا پیش از خرید جهت استعلام قیمت با کارشناسان ما تماس بگیرید.